| Model | 3.5kW+5kWh | 6.6kW+10kWh | 6.6kW+16kWh | 12.5kW+30kWh | 25kW+60kWh | 37.5kW+90kWh | 50kW+120kWh |
| Inverted Output |
| Rated Output Power(W) | 3500 | 6600 | 6600 | 12500 | 25000 | 37500 | 50000 |
| Max. Peak Power(W) | 6000 | 10000 | 10000 | 19000 | 38000 | 57000 | 76000 |
| Inverter to Bypass Switch Time(ms) | 10((Typical) |
| Battery |
| Battery Capacity(kWh) | 5 | 10 | 16 | 30 | 50 | 80 | 100 |
| Charge/Discharge Rate(C) | 0.5 | 1 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
| PV Charging |
| Number of MPPT Trackers | 1 | 1 | 1 | 2 | 4 | 6 | 8 |
| Max. PV Array Power(W) | 4000 | 6600 | 6600 | 6600*2 | 6600*4 | 6600*6 | 6600*8 |
| Max. PV Input Current(A) | 13 | 22 | 22 | 22*2 | 22*4 | 22*6 | 22*8 |
| Max. Open Circuit Voltage(VDC) | 500 | 500 | 500 | 500*2 | 500*4 | 500*6 | 500*8 |
| MPPT Operating Voltage Range(VDC) | 120~450(single-phase)/200~650(three-phase) |
| Grid Input |
| Input Voltage Range(VAC) | 90~280/170~280 |
| Frequency Range(Hz) | 50/60±0.3 |
| Protection&General Parameters |
| Protection level | IP20 |
| Dimensions (W × D × H, mm)mm | 210*640*791 | 410*610*811 | 245*800*883 | 470*800*881 | 1090*635*1950 | 1090*1240*1530 | 1090*1240*2040 |
| Weight(kg) | 70 | 140 | 170 | 290 | 625 | 960 | 1180 |
| Note: 12.5kW+32kWh optional three-phase inverter, 25kW+50kWh/37.5kW+80kWh/50kW+100kWh are all three-phase inverters; |